(with systém of quick preheating and 4-stage automatic prick material)

Facility purpose

Manual gas console serve to pressure gas adjustment for autogennic cutting process. This alignment is performing with help of eight regulative valves:

MPK

  • GAS 1 . alignment of low pressure preheating gas
  • GAS 2 . alignment of high pressure preheating gas
  • OXY 1 . alignment of low pressure preheating oxygen
  • OXY 2 . alignment of high pressure preheating oxygen
  • CUT [1-4] . alignment of 4-stage pressure cutting oxygen
Each regulative valve is activated by soleinoid valve. Low pressure of heated gas and oxygen is used during cutting itself. High pressure of heated gas and oxygen is used for material preheating before start of the cutting oxygen. Regulative valves of cutting oxygen serving to progressive pressure (4-stage) increasing during material perforation. It is recommend till 100mm material thickness. Annexation to control panel with help of Relé contacts.

Basic facilities

  • panel with eight regultive and eight solenoid valves.
  • control case
  • feeding cabel
Technical specification
number of regulative valves 8
power suply 230V/50Hz
maximal values of input pressures 15bar heating gas
15bar heating oxygen
15bar cutting oxygen
maximal values of output pressures 4bar heating gas
4bar heating oxygen
10bar cuting oxygen (can be even 15 bars if customer wishes so)

 